OPERATING INSTRUCTIONS
King Electric’s Instant Alert Monitor is designed to alert the installer if continuity in the heating
wire is broken by cutting the wire or if there is a short circuit between the ground and heating
wires. Connect the Instant Alert Monitor to your Floor Heating Cable or Mat System BEFORE
starting installation and leave it connected until the job is COMPLETE.
PREPARATION
1. Remove the battery compartment cover on the back of the Instant Alert Monitor. Insert two
(2) AAA size batteries into the compartment. Make sure the batteries are installed in the correct polarity
according to the symbols in the battery compartment.
2. Replace the battery compartment cover. Switch the unit to the “ON” position to activate Instant Alert
Monitor
3. Since the Instant Alert Monitor is not connected to a mat or Floor Heat Cable system, the alarm should
sound and the red alarm indicator light should be lit. If the red alarm indicator light does not go on, and
you do not hear the alarm sound, then remove the battery compartment and inspect the battery
connections. Correct the polarity or replace the batteries.
4. Turn the Monitor “OFF”
INSTALLATION
1. Loosen the 3 terminal screws
2.a For One Cable or Mat: See FIG 1
a. Insert the ground wire from the cable into the E
terminal on the front of the device and tighten
the E terminal screw.
b. Insert the one of the two heating lead wires
from the cable (black and white (120V) or
black and red (240V)) into the L1 terminal from
the front of the device. Insert the other into the
L2 terminal. Tighten the L1 and L2 screws.
2.b For up to Three Cables or Mats: See FIG 2 or
FIG 3.
a. Insert the Black heating lead wire from the
heating cable into the L1 terminal from the
front of the device and tighten the screw.
b. Insert the White for 120V or Red for 240V
heating lead wire from a DIFFERENT heating
cable into the L2 terminal and tighten screw.
c. Connect the remaining heating lead wires so
that the mats are connected in series.
d. Connect all ground wires together and connect
them to the E terminal and tighten screw.
3. A green light indicates that the device is operating
properly and does not sense damage in the cable.
800-603-5464 king- electric.com
ON
OFF
Vue de la page 0
1 2

Résumé du contenu

Page 1

OPERATING INSTRUCTIONS King Electric’s Instant Alert Monitor is designed to alert the installer if continuity in the heating wire is broken by cu

Page 2 - WARNINGS

OPERATION IMPORTANT: Make sure that the Floor Heating Cables or Mat systems which will be monitored ARE NOT connected

Commentaires sur ces manuels

Pas de commentaire